请问我的DB-120-B1 还有救吗?
机子不小心刷坏了现在买了TTL线读出的数据CFE version 1.0.37-10.3 for BCM96358 (32bit,SP,BE)
Build Date: Thu May 10 22:28:34 CST 2007 (root@localhost.localdomain)
Copyright (C) 2000-2006 Broadcom Corporation.
Boot Address 0xbe000000
Initializing Arena.
Initializing Devices.
Parallel flash device: name AM29LV320MT|S29GL128-A, id 0x2201, size 16384KB
Flash Layout: Boot Kern
AuxFS Misc PSI
Flash RootFS Partition Length: 14942208
Auto-negotiation timed-out
10 MB Half-Duplex (assumed)
CPU type 0x2A010: 300MHz, Bus: 133MHz, Ref: 64MHz
CPU running TP0
Total memory: 33554432 bytes (32MB)
Total memory used by CFE:0x80401000 - 0x80528200 (1208832)
Initialized Data: 0x8041DA80 - 0x8041FA20 (8096)
BSS Area: 0x8041FA20 - 0x80426200 (26592)
Local Heap: 0x80426200 - 0x80526200 (1048576)
Stack Area: 0x80526200 - 0x80528200 (8192)
Text (code) segment: 0x80401000 - 0x8041DA80 (117376)
Boot area (physical): 0x00529000 - 0x00569000
Relocation Factor: I:00000000 - D:00000000
** Flash image not found. **
*** Break into CFE console ***
Board IP address : 192.168.1.1:ffffff00
Host IP address : 192.168.1.100
Gateway IP address :
Run from flash/host (f/h) : f
Default host run file name : vmlinux
Default host flash file name : bcm963xx_fs_kernel
Boot delay (0-9 seconds) : 1
Board Id (0-8) : 96358VW2
Number of MAC Addresses (1-32) : 11
Base MAC Address : 02:10:18:01:00:01
PSI Size (1-64) KBytes : 24
Flash Block Size (1-128) in KBytes: 64
Auxillary File System Size Percent: 8
Main Thread Number : 0
web info: Waiting for connection on socket 0.
CFE>
==============================================
请问各位大大我这设备还有救吗?
好像通过tftp方法可以修复,具体步骤在论坛上找 回复 silon 的帖子
tftp可能也难,ping 都没反应了。(daku: 能进CFE应该还能有救。
而且你现在是卡在Flash中没有读取到固件而已。
试试看看进入CFE的固件页面重新刷新一下。
至于Ping的问题,换个Lan口试试。 插到LAN4口,设置好IP地址 Flash Block Size (1-128) in KBytes: 64 改成128试试