hzjunen 发表于 2009-8-6 01:09:44

紧急求助:DB120刷成这样了,请高手指点!!!

CFE version 1.0.37-6.5 for BCM96358 (32bit,SP,BE)
Build Date: Tue Jan 27 11:04:51 CST 2009 (root@MOD6538)
Copyright (C) 2000-2005 Broadcom Corporation.
Boot Address 0xbe000000
Initializing Arena.
Initializing Devices.
Parallel flash device: name AM29LV320MT, id 0x2201, size 16384KB
Unknown PHY type
CPU type 0x2A010: 300MHz, Bus: 133MHz, Ref: 64MHz
CPU running TP0
Total memory: 33554432 bytes (32MB)
Total memory used by CFE:0x80401000 - 0x80528320 (1209120)
Initialized Data:          0x8041DB70 - 0x8041FA20 (7856)
BSS Area:                  0x8041FA20 - 0x80426320 (26880)
Local Heap:                0x80426320 - 0x80526320 (1048576)
Stack Area:                0x80526320 - 0x80528320 (8192)
Text (code) segment:       0x80401000 - 0x8041DB64 (117604)
Boot area (physical):      0x00529000 - 0x00569000
Relocation Factor:         I:00000000 - D:00000000
*** Board is not initialized properly ***
Press:<enter> to use current value
      '-' to go previous parameter
      '.' to clear the current value
      'x' to exit this command
Board Id Name (0-8)
96358M         -------0
96358SV          -------1
96358VW          -------2
96358VW-16       -------3
96358GW-16       -------4
96358GW          -------5
96358GW-A      -------6
96358VW2         -------7
96358VW-A      -------8       :7

woaizca 发表于 2009-8-6 08:22:42

有啥問題?

krisp 发表于 2009-8-6 10:18:49

接着把设置做完重启就ok了

sthong 发表于 2009-8-6 10:46:34

hzjunen 发表于 2009-8-6 17:24:40

请问是Press:<enter> to use current value
      '-' to go previous parameter
      '.' to clear the current value
      'x' to exit this command
Board Id Name (0-8)
96358M         -------0
96358SV          -------1
96358VW          -------2
96358VW-16       -------3
96358GW-16       -------4
96358GW          -------5
96358GW-A      -------6
96358VW2         -------7
96358VW-A      -------8       :7设置这段吗?

yjjq 发表于 2009-8-6 20:16:30

看你刷哪一个固件的

吻到心伤透 发表于 2009-8-6 20:17:34

设置完后重启,
再刷一遍固件就成功了。

hzjunen 发表于 2009-8-7 22:25:01

我刷的是DLINK 2740B firmware V 2.97 build 101
*** Board is not initialized properly ***
Press:<enter> to use current value
      '-' to go previous parameter
      '.' to clear the current value
      'x' to exit this command
Board Id Name (0-8)
96358M         -------0
96358SV          -------1
96358VW          -------2
96358VW-16       -------3
96358GW-16       -------4
96358GW          -------5
96358GW-A      -------6
96358VW2         -------7
96358VW-A      -------8       :7
请问是把96358VW2         -------7的改成6吗?路由型号db120wg
再次谢谢各位

哈哈6014 发表于 2009-8-7 23:59:44

改成5,96358GW,这是根据固件来选的
页: [1]